SERVICE CALL CONDITIONS April 2007

4-42

SC codes Group 4: Image Development - 2
ID sensor error 1: Calibration SC400 D
Before adjustment Vsg_reg<0.5 but
Vsg_reg could not be adjusted to the
target Vsg_reg = 4.0±0.2V during
process control.
ID sensor harness disconnected,
loose, defective
ID sensor dirty
ID sensor defective
ITB unit drawer connector dirty
Note: Vsg_reg is the voltage reading of the light reflected directly from the bare
surface of the ITB. The color ID sensor is provided with one additional r eceptor
to read diffuse light reflected from the colors of ID sensor patterns. T he
additional receptor on the color sensor is not used to read the bare surf ace of
the belt. For more, see Section "6. Details".
SC410 D
ID sensor error 2: Development γ K
SC411 D
ID sensor error 3: Development γ M
SC412 D
ID sensor error 4: Development γ C
SC413 D
ID sensor error 5: Development γ Y
Development gamma for black,
magenta, cyan, or yellow is not
within range (0.3 to 6.0).
Process control halts when this
SC is issued.
Toner density not normal: Refer to the
procedure for process control self-check
error codes 55 to 59 to 59, and 61
(section 4.2.4)
Potential sensor defective
Laser diode not firing
ITB separation for CMY abnormal
Transfer power pack defective
ID sensor defective
SC414 D
ID sensor error 6: Development start voltage K
SC415 D
ID sensor error 7: Development start voltage M
SC416 D
ID sensor error 8: Development start voltage C
SC417 D
ID sensor error 9: Development start voltage Y
The development start voltage
in the development of the
black, magenta, cyan, or
yellow PCU is not within the
correct range (±150V)
Toner density not normal: Refer to the
procedure for process control self-check
error codes 55 to 59, and 61 (section
4.2.4)
Potential sensor defective
LD not firing correctly
ITB separation for CMY abnormal
Transfer power pack defective
ID sensor defective
LED error during Vsg adjustment SC418 C
PWM value: Ifsg>2000
This means the current to the LED of the
ID sensor is abnormal.
ID sensor dirty
ID sensor defective