PCU (PHOTOCONDUCTOR UNITS) August, 2006
3-54
3.5.5 PCU CLEANING UNIT
Remove:
PCU (3.2.7)
Charge roller unit (3.5.3)
Drum (3.5.4)
[A]: PCU joint
[B]: Rear bracket ( x1)
[C]: Long sleeve
[D]: Leaf spring
[E]: Short sleeve
[F]: Bracket and 2 gears ( x1)
[G]: Cleaning unit
When you remove the cleaning unit, the mylar can catch on the PCU frame
and will scatter toner. To prevent this, rotate then lift
The cleaning unit contains these PM parts: lubricant brush, toner brush.
2
1
B132R208.WMF
[A]
[B]
[C]
[D]
[E]
[F]
[G]