SERVICE PROGRAM TABLES April, 2007 5-30
1200
1st CMP Down
This SP adjusts the temperature of the heating roller at the start of the CMP dow n
modes for black-and-white copying in normal/high temperature environment s.
1st CPM Down 1st CMP Down (Heating Roller Temperature)
001 StrTemp:Low/Hi:1C
002 StrTemp:Low/Hi:FC Normal temperature, high temperature environment
[–20~0/1 deg.]
003 StrTemp:Low:1C
004 StrTemp:Low:FC Low temperature environment
[–20~0/1 deg.]
005 CPM Norm/Hi:1C Normal, high temperature environment, A4 SEF
[10~60/5 cpm]
006 CPM Norm/Hi:FC Normal, high temperature environment, A4 SEF
[10~60/5 cpm]
007 CPM Low Temp:1C Low temperature environment, A4 SEF
[10~60/5 cpm]
008 CPM Low Temp:FC Low temperature environment, A4 SEF
[10~60/5 cpm]
2nd CPM Down 2nd CPM Down
009 CPM Norm/Hi:1C Normal, high temperature environment, A4 SEF
[10~60/5 cpm]
010 CPM Norm/Hi:FC Normal, high temperature environment, A4 SEF
[10~60/5 cpm]
011 CPM Low:1C Low temperature environment, A4 SEF
[10~60/5 cpm]
012 CPM Low:FC Low temperature environment, A4 SEF
[10~60/5 cpm]
3rd CPM Down:Thk 3rd CPM Down: Thick Paper
013 1C:60/45/30cpm CPM down settings (based on A4 SEF) for black and white.
[0~4/1]
0: 60 cpm 1: 50 cpm 2: 45 cpm 3: 30 cpm
014 FC:45/25/15cpm CPM down settings (bas ed on A4 SEF) for full color.
[0~4/1]
0: 60 cpm (This function is not use in this model.)
1: 50 cpm 2: 45 cpm 3: 30 cpm
015 (0:Yes 1:No) Switches the CPM down feature ON/OFF
0:OFF 1:ON
1201
HtgRoll L2:Hys Heating Roller 2: Hysterisis On/Off
This SP adjusts the control temperature of the heating roller when Lamp 2 in the
heating roller is switched ON.
001
On [-5.0~+5.0/0.5]
Note: Every “0.1” increment adjusts temperature “0.1 deg.”
002
Off Switches OFF Lamp 2, no adjust allowed.