PM COUNTER August, 2006
2-4
Number button submenu
Press any number button to open the submenu for a part. In the example below,
the number button [001] #K:PCU was pressed.
[A]: Clear current counter. Press to reset the selected PM counter (in this
example 001 #K:PCU) to "0". You can also clear the settings by pressing the
[Clear] button on the right side of the PM Counter Main Menu ([F] on the
previous page).
[B]: Change target yield. Press the change the target PM yield. To change the
setting:
Press [Change target yield]
Enter the number for the new target with the 10-key pad.
Press [#] on the operation panel.
[C]: PM yield indicator settings. [Yes] is the default. Press [No] to remove the
current item from the "Parts list for PM yield indicator".
When set to "Yes", items marked with the # ma rk (# = a unit) will not have
their individual items displayed automatically in the "Parts list for PM yield
indicator list".
When set to "No", items marked with the # mark (# = a unit) only the
individual components will appear in the list (the units will not appear).
[D]: PM counter history. This is a summary of the most recent counts
Latest 1. The latest PM count since the unit (or part) was replaced.
Latest 2. The previous PM count since the unit (or part) was replaced.
Latest 3. The previous but one PM count since the unit (or part) was
replaced.
B132P904.BMP
[A]
[B]
[C]
[D]