August, 2006 ARDF
6-19
Detailed
Descriptions
Changing the Default Selection with SP6016 and SP5126
Some original sizes are almost the same. The machine cannot detect a difference
between these sizes. Because of this, you can force the machine to detect one size
or the other size with SP6016.
1. Enter the SP mode.
2. Select SP6016.
On the screen you will see an 8-digit binary setting bar: 00000000
The default settings are all "0".
In North America, the size recognition is changed with Bits 3 to 0 (other bits
are ignored):
Bit7
Bit6
Bit5
Bit4
Bit3 Bit2 Bit1 Bit0
--- --- --- ---
0 = LG SEF
0 = LT SEF 0 = LT LEF 0 = DLT SEF
--- --- --- --- 1 = SP 5126
(default =
F4 SEF)
1 = 8" x 10" SEF 1 = EXE LEF 1 = 11" x 15" SEF
In Europe, the size recognition is changed with Bits 2 to 0 (other bits are
ignored):
Bit7
Bit6
Bit5
Bit4
Bit3 Bit2 Bit1 Bit0
--- --- --- --- --- 0 = LT LEF 0 = LT SEF 0 = DLT SEF
--- --- --- --- --- 1 = 16 Kai LEF 1 = 16 Kai SEF 1 = 8 Kai SEF