SPECIAL PROCEDURES April, 2007 4-22
General Displayed
Code Item Major Cause Action
61 LD Failure A laser diode failed to fire and
write the ID sensor pattern.
Toner shield glass dirty
PCU set incorrectly
Laser diode defective
1. Copy the color test pattern to determine which color is abnormal.
2. Turn the machine OFF.
3. Open the front door, remove the toner supply unit and check the
toner shield glass for dirt.
4. Reassemble the machine, switch the machine ON, then do SP3820
001.
Notes
The probes of the potential sensors of each PCU are located at
different positions. This failure can be caused by installing a
potential sensor at the incorrect position. However, you can
eliminate this as a cause if a new PCU is installed. (A guide ensures
prevents a PCU from being installed at the wrong location.)
If the machine fails to return SC240 to SC243, you can eliminate a
defective LD as the cause of the problem.
62 Vr Error Vr (residual voltage) greater than
–200V.
Drum deteriorated
Toner shield glass dirty
Open the front door, remove the toner supply unit, and check the
toner shield glass for dirt.
Clean the glass then do SP3820 001.
If this does not solve the problem, replace the drum.
63 Vd Adjust
Error Vd could not be adjusted within
±10V.
Charge roller dirty
Drum defective
Replace the charge roller
Replace the drum.
Potential
Adjustment
64 Vpl Adjust
Error Vpl could not be adjusted within
±5V.
Drum deteriorated due to
filming
Charge roller dirty
Replace the charge roller
Replace the drum.
90 Potential
Adjust Error SP3501 (potential control method)
is set to 1 (Fixed). Do SP3501 001 and select "0" (Auto).
Abnormal
End 99 Forced
Termination Door open, power OFF, or other
problem interfering with process
control self-check.
Make sure the machine is turned ON.
Make sure the front door is closed completely.