SERVICE PROGRAM TABLES April, 2007 5-64
2751
Sp1 K Bias Set Bias for Special Paper 1: K
These SPs set the standard values of the electrical charges that are applied to 1)
create bias for image transfer from drum to ITB, 2) create bias for image transf er
from ITB to paper (PTR), and 3) neutralize the charges on the both sides of the
paper to separate the paper from the ITB (SepDC, SepAC). These settings are used
when printing on Special Paper 1 in the black-and-white mode and are applied only
to the image area.
001
ITB [0~500/0.1 µa]
007
Side1:PTR [-100~0/1 µa]
008
Side1:SepDC [0~100/0.1 µa]
009
Side1:SepAC [80~120/0.1 kV]
012
Side2:PTR [-100~0/0.1 µa]
013
Side2:SepDC [0~100/0.1 µa]
014
Side2:SepAC [80~120/0.1 kV]
2756
Sp1 K Bias Set Bias for Special Paper 1: K
These SPs set the standard values of the electrical charges that are applied to 1)
create bias for image transfer from drum of each color (Y, M, C, K) to the ITB, 2)
create bias for image transfer from ITB to paper (PTR), and 3) neutralize the charges
on the both sides of the paper to separate the paper from the ITB (SepDC, SepAC).
These settings are used only for Y, M, C, K when printing on Special Paper 1 in the
full-color mode and are applied only to the image area.
001
ITB:K [0~500/0.1 µa]
002
ITB:M [0~500/0.1 µa]
003
ITB:C [0~500/0.1 µa]
004
ITB:Y [0~500/0.1 µa]
013
Side1:PTR [-100~0/1 µa]
014
Side1:SepDC [0~100/0.1 µa]
015
Side1:SepAC [80~120/0.1 kV]
021
Side2:PTR [-100~0/1 µa]
022
Side2:SepDC [200~1000/0.1 µa]
023
Side1:SepAC [80~120/0.1 kV]