INSTALLATION REQUIREMENTS August, 2006
1-2
6. If the installation area has air-conditioners or heaters, put the machine in a
location that agrees with these conditions:
a) Where there are no sudden temperature changes from low to high, or
high to low.
b) Where it will not be directly exposed to cool air from an air conditioner in
the summer.
c) Where it will not be directly exposed to reflected heat from a heater in the
winter
7. Do not put the machine where it will be exposed to gases that can cause
corrosion.
8. Put the copier on a strong and level surface. The front and rear of the machine
must be less than ±5 mm (0.2") away from level.
9. Do not put the machine where there could be strong vibrations.
10. Do not connect the machine to the same power source as other electrical
devices.
11. The machine can make an electromagnetic field, and this can cause
interference with radio or television reception.
1.1.2 MACHINE LEVEL
1. Front to rear: Less than ±5 mm (0.2") away from level
2. Right to left: Less than ±5 mm (0.2") away from level
The machine legs can be turned to adjust them up or down, to make the machine
level. Put a carpenter’s level on the exposure glass.