August, 2006 ARDF INPUT/OUTPUT CHECK

5-203

5.7.2 ADF OUTPUT CHECK: SP6008

1. Open SP mode SP6008.

2. Select the SP number that corresponds to the component you wish to check.

(Refer to the table below.)

3. Press On then press Off to test the selected item. You cannot exit and close

this display until you click Off to switch off the output check currently executing.

6008 ADF Output Chk ADF Output Check
Turns on the ADF electrical components individually for testing. Select the
component to test, then press the "ON" button. Besure to press the "OFF" button
as soon as you hear the component turn on.
001
ADF Feed M:Fwd 007
ADF Bot Inv M:Fwd
002
ADF Feed M:Rev 008
ADF Bot Inv M:Rev
003
ADF Trans M:Fwd 009
ADF Pick-up M:Fwd
004
ADF Ext M:Fwd 010
ADF BotPlt M:Rev
005
ADF Top Inv M:Fwd 011
ADF Top Inv SOL
006
ADF Top Inv M:Rev 012
ADF Bot Inv SOL