SERVICE CALL CONDITIONS April 2007 4-54
Hot roller thermistor error 3: Software - High Temperature SC563 A
The thermistor detected a
temperature over 250°C 10
times within 1 sec.
TRIAC short
IOB defective
BICU defective
Fusing temperature control is erratic
Do SP5810 to cancel the SC fusing code.
Hot roller thermistor error 4: Hardware - High Temperature SC564 A
The thermistor detected a
temperature over 260°C. TRIAC short
IOB defective
BICU defective
Fusing temperature control is erratic
Do SP5810 to cancel the SC fusing code.
Hot roller thermistor error 5: Lamp remains ON SC565 A
After hot roller reaches warmup
temperature, the hot roller fusing
lamp remains for 6300 sec.
while the hot roller is not
rotating.
Thermistor damaged, or out of position
Fusing lamp disconnected, broken
Do SP5810 to cancel the SC fusing code.
Double-feed sensor error SC585 C
The output of the double-feed
sensor reaches the upper or
lower limit
Double-feed sensor connector is not
connected correctly.
Double-feed sensor is dirty with paper
dust.
There is paper or foreign material
between the receptor and LED of the
double-feed sensor.