April, 2007 SERVICE CALL CONDITIONS

4-55

SC codes Group 6: Device Communication
ARDF communication error SC620 D
A BREAK signal occurs after the
machine detects the ARDF, or a
communication timeout occurs.
ARDF disconnected
IPU board harness disconnected,
defective
IPU board defective
Spurious noise from the power supply
line
ARDF control board defective
Mailbox-to-Finisher communication error SC621 D
Communication between the
mailbox and finisher is
interrupted. An ACK/NCK signal
was not received within 100 ms
after a data frame is sent and 3
retries failed.
Connection cable between mailbox and
finisher disconnected, defective
Finisher main board defective
BICU defective
PSU defective
LCT communication error SC622 D
Communication between the
copier and LCT is interrupted.
An ACK/NCK signal was not
received within 100 ms after a
data frame is sent and 3 retries
failed.
Connection cable between the LCT and
copier is disconnected, defective
LCT main board defective
BICU defective
PSU defective
Mailbox-to-copier communication error SC624 D
Communication between the
mailbox and copier is
interrupted. An ACK/NCK signal
was not received within 100 ms
after a data frame is sent and 3
retries failed.
Mailbox cable disconnected, defective
Mailbox main board defective
BICU defective
PSU defective