August, 2006 ARDF
6-27
Detailed
Descriptions
4. Side 2 of original is scanned, lower inverter junction gate [A] opens and
directs to lower inverter table [B]. Original feeds.
5. Steps 1, 2, 3 repeat for original . Lower inverter junction gate [C] and upper
inverter junction gate [D] remain closed. Lower inverter rollers [E] feed original
to exit rollers [F]
6. The exit rollers feed original to the original exit tray. Original is corrected
for skew and is scanned. Skew is corrected only for small paper sizes (B6, A5,
HLT). Other sizes can be selected for this function with SP6020.
31
2
B132D115.WMF
B132D117.WMF
B132D118.WMF
[A]
[B]
[C]
[D]
[E]
[F]