April, 2007 SERVICE PROGRAM TABLES 5-79
2903
Env Thresh:K_PCU Room Temperature Correction Threshold: PCU
This SP sets the threshold value of LL and ML for the current room temperature.
001
Abs Humid:Thresh1 [0~10,000 / 0.01 g/m3]
002
Abs Humid:Thresh2 [0~10,000 / 0.01 g/m3]
003
Abs Humid:Thresh3 [0~10,000 / 0.01 g/m3]
004
Abs Humid:Thresh4 [0~10,000 / 0.01 g/m3]
2904
Blade Bend Ctrl Blade Bend Prevention Pattern Control
A blade-bend prevention pattern is created with K toner on the ITB between ever y
copy image to lubricate the ITB cleaning blade so it will not bend or scour the
surface of the ITB. These SPs set 1) pattern creation interval, 2) density of the
pattern, 3) whether the pattern is displayed.
Note: This function is OFF. Changing this setting is normally not required for this
machine.
001
Pattern Interval Sets the number of pages between patterns.
[0~200/1 pg.]
002
Pattern Light Sets the density of the pattern.
[0~63/1]
003
Page Cnt Disp Displays the count for the number of blade prevention
patterns.
[0~200/1 pg.]
2905
Used Toner Mtr 2 Used Toner Motor 2 (Waste toner distribution motor)
Control
The waste toner bottle is provided with a near-full sensor and an auger that evenly
distributes the used toner inside the bottle. To extend the life of the waste toner
distribution motor that rotates this auger, the motor and auger do not operate
continuously. The motor is turned ON only after a prescribed amout of toner has
been consumed.
001
Toner Consumed Sets the amount of toner to be used before the toner
[1~10/1 g]
002
Waste Tnr M Time Se ts the amount of time the motor remains ON.
[1~10/1 sec.]