SPECIAL PROCEDURES April 2007
4-24
To adjust the main machine:
1. Place the test charge Connection Kit Color Test Chart (P/N VSST9501) on the
exposure glass, with the arrow mark on the chart aligned with the left rear
corner.
2. Do SP4954 001 (Read/Restore Std) and press [Execute].
After about 10 seconds, the "Completed" message appears.
Important: If "Completed" appears immediately after pressing [Execute], the
adjustment may have failed. Do the procedure again.
3. After doing SP4954 001, do the ACC procedure. For more, see Section "1.
Installation (Pg.1-33)"
To adjust the sub machine:
4. Do Steps 1 to 3 for the sub machine.
Compare the results
5. Set the two machines for full color, and do some sample color copies.
6. Compare the results from the two copiers. If the results are not good, do the
procedure again from step 1.