SERVICE PROGRAM TABLES April, 2007 5-46
2302
Temp/Humid Disp Temperature/Humidity Display
This SP displays the current temperature and humidity. These readings are out put
by the temperature humidity display located on the bottom of the machine below the
waste toner bottle.
001
Temp Disp Room temperature (oC).
[0~100/1 deg.]
002
Rel Humidity Disp Relative humidity (saturation point at current temperature).
[0~100/1 %rh.]
003
Abs Humidity Disp Absolute humidity.
[0~1000/m2]
004
Current Env Disp Displays the current environment control mode. The
control modes are divided into 5 levels: LL, ML, MM, MH,
HH. These levels are determined by thresholds
determined for the other readings of this SP and the
reading of the absolute humidity (SP2301 003).
2303
Force Temp Corr Force Ambient Temperature Correction DFU
The temperature/humidity sensor reading is used to adjust settings during proc ess
control when this SP is set to zero (the default). The value of the absolute humidity
reading displayed by SP2302 003, as well as the other readings of the conditions
around the machine displayed with SP2302, are used in the process control
calculations. If you press any key (1 to 5) below, the value you select is used and the
readings of the temperature/humidity sensor are ignored.
Note: After you press any key (1 to 5), the setting you select remains in effect only
while the machine is in the SP mode. Once you leave the SP mode, this SP is reset
to zero automatically.
0 Sensor Detect
1 LL
2 ML
3 MM
4 MH
5 HH
2304
Set Humid Thresh Ambient HumidityThreshold Setting
Sets the threshold values for the absolute humidity of the current LL and ML settings
for the main machine in the present environment.
001
Abs Humid:Thresh1 [0~1000g/m3]
002
Abs Humid:Thresh2 [0~1000g/m3]
003
Abs Humid:Thresh3 [0~1000g/m3]
004
Abs Humid:Thresh4 [0~1000g/m3]
2306
Vd Link Corr Vd Link Correction
No information is available at this time.
001
Set [0~1/1] 0:Off, 1: On
002
Correction Coeff [0.01~2.5/0.01]