April, 2007 ADDITIONAL INFORMATIONS
4-93
Machine Status Transition time setting in UP:
User Tools System Settings
Timer Settings
Hot Roller
Heater
ON/OFF
SP number for Hot
Roller Temperature
Warming Up 9 min (Fixed) ON SP 1105 2
Operation - OFF -
Stand-by Mode - ON MM: SP 1105 36
LL: SP 1105 37
HH: SP 1105 38
Panel-off Mode Panel-off Timer
Default: 60 sec. (10 to 999 sec) ON (Same with Stand-by
Mode)
Low Power Mode
Energy Saver Timer
Default: 15 min (1 to 240 min) ON SP 1202 11
Auto Off Mode Auto Off time
Default: 90min (1 to 240 min) OFF -
Refer the diagram in the service manual "6.17.4 ENERGY SAVER MODE".