April, 2007 SERVICE PROGRAM TABLES

5-81

3003 Vtref:Disp/Set Set/Display Vtref
This SP displays the TD sensor target voltage. This target voltage is inversely
proportional to the density of the toner:
If the target is high, toner density is lowered. If the target is low, toner density is raised.
The machine uses readings of the ID sensor patterns between pages to determine
the amount of toner coverage and compared with the threhold values for the upper
and lower limit of coverate. The result of this calculation is used to calcul ate Vtref.
Note: Vtref is the TD sensor reference voltage. It is frequently updated to stabilize
the toner concentration in the development unit.
001
Current Val:K
002
Current Val:M
003
Current Val:C
004
Current Val:Y
[0~5.00/0 V]
005
Initial Val:K
006
Initial Val:M
007
Initial Val:C
008
Initial Val:Y
[0~5.00/0 V]
3021
Set Vt Shift Set Vt Shift Amount
Use this SP to correct Vt (TD sensor output voltage) in the low speed mode
(128~256 g/m2). The machine then uses this value to calculate Vt for low speed
mode.
001
Shift (Low Spd):K
002
Shift (Low Spd):M
003
Shift (Low Spd):C
004
Shift (Low Spd):Y
[0~500/0 V]