To remove the face plate
8. Rotate the transfer belt release lever [A] counter-clockwise until it stops.
9. Disconnect the fan connector [B].
10. Remove the face plate [C] ( x5).
11. Place the PCU stand [D] on a flat surface.
NOTE: The PCU stand is mounted on a rack attached to the bottom of the
copier with magnets.
12. Wipe the surface of the stand with a clean cloth to remove dust.
B132R201.WMF
B132I902.WMF
[D]