SERVICE PROGRAM TABLES April, 2007 5-84
3194
ID Coeff Display ID Sensor Sensitivity Coefficient Display
Displays the most recent and averaged readings of the sensitivity correction coef fients
(K2 and K5).
001
K2:Col:Last
002
K5:Col:Last
005
K2:Col:Ave
006
K5:Col:Ave
[0~10000/0]
3251
Tnr Supply Time Toner Calibration Time: Display
Displays for confirmation the length of time the toner supply clutch remained on to
send toner to the sub hopper after a new toner cartridge was installed.
001
K
002
M
003
C
004
Y
[0~10000/1 sec.]
005
Toner Pump CL:K
006
Toner Pump CL:M
007
Toner Pump CL:C
008
Toner Pump CL:Y
Use these SPs to display the accumulated drive time for
each powder pump clutch before installing a new one.
These SPs are reset to zero after the clutches are replaced.
3301
Tnr Supply Select Toner Supply Method
001
K
002
M
003
C
004
Y
[0~1/1]
0: Fixed toner supply
1: PID Toner Supply
3302
Tnr Supply Select Toner Supply Rate
Sets the toner supply rate for fixed toner supply mode. The rate is set by adjusting the
on time of the toner supply clutch. This setting is used only if SP3301 is set to "0".
001
Supply Rate:K
002
Supply Rate:M
003
Supply Rate:C
004
Supply Rate:Y
[0~100 / 1 %]