April, 2007 SERVICE PROGRAM TABLES

5-29

1110
Paper Type Selet Paper Type Select
These SP settings switch the ON/OFF the paper type type detection and double-
feed functions.
[0~1/1]
0: Enable
1: Disable
Two sensors, one mounted above and one below the paper at the registration
rollers, detect the opacity of the first sheet and compares this reading for every
subsequent sheet. If the reading is higher (thicker paper) or lower (thinner paper)
the sensor triggers an error.
Paper Type
001
Tray 1
002
Tray 2
003
Tray 3
004
Tray 4 Japan Only
005
Bypass
006
LCT
Double-Feed
007
Tray 1
008
Tray 2
009
Tray 3
010
Tray 4 Japan Only
011
Bypass
002
LCT
1111 Nip Width Mode Nip Width Measurement Setting Mode
001 Execute Determines whether the nip at the hot roller and pressure
roller is calibrated. Press [Execute].
002 Stop Time Determines the down time of the fusing/exit motor in the
fusing nip band calibration mode.
[1~100/1 sec.]
003 Stop Interval Determines the intervals between the down times of the
fusing/exit motor in the nip band calibration mode.
[0~2000/100 msec.]
1112
Fuser Unit In/Out Fusing Unit: In/Out – Start Fusing Unit
Determines whether the fusing unit operates during the copy cycle for image
creation and paper feed.
0:OFF, 1:ON