August, 2006 IMAGE ADJUSTMENTS
3-179

3.19.2 ARDF

ARDF side-to-side and leading edge registration

Make a temporary test chart as shown above using A3/DLT paper.
1. Place the temporary test chart on the ARDF table and make a copy.
2. Check the registration, and adjust using the following SP modes if necessary.
SP Code What It Does Adjustment Range
SP6006 001 ADF Main Reg Adj ± 3.0 mm
SP6006 003 ADF Sub Reg Adj ± 29 steps
SP6006 005 ADF Buck Adj:Front ± 20 steps
SP6006 006 ADF Buck Adj:Back ± 20 steps
SP6006 007 ADF TEdge EMargin ± 20 steps
B146R964.WMF
B
A
B146R965.WMF
A: Leading edge registration
B: Side-to-side registration