April, 2007 SERVICE CALL CONDITIONS

4-65

SC800: Overall System
Boot loader error SC817
C
The boot loader cannot read one of the
following: self-diagnostic module, kernel, or one
of the files of the root file system, or the check
of one of these items on the system SD card
failed.
File or module on the system
SD card is corrupted
File or module on the system
SD card is illegal
Make sure that the system
SD card is the one designed
for the machine
Replace system ROM on the
controller board

Watchdog error
SC818
C
While the system program is
running, a bus hold or interrupt
program goes into an endless loop,
preventing any other programs from
executing.
System program defective; switch
OFF/ON, or change the controller
firmware if the problem cannot be solved
Controller board defective
Controller option malfunction

Fatal kernel error
Due to a control error, a RAM
overflow occurred during system
processing. One of the following
messages was displayed on the
operation panel.
System program defective
Controller board defective
Optional board defective
Replace controller firmware
0x696e init died
0x766d vm_pageout: Virtual
Memory is full
4361 Cache Error
SC819
C
Other
NOTE: For more details about this SC code error, execute SP5990 to print an SMC

report so you can read the error code. The error code is not displayed on the

operation panel.