April, 2007 SERVICE CALL CONDITIONS

4-75

4.3.4 ADDITIONAL SC CODES PRINTED IN SMC REPORTS

These codes are also used in the SMC report.

Codes that have the same number in this series are identified by an additional 4-

digit hexadecimal number.

SC No. Symptom Possible Cause
IEEE802 11b card startup error 853
D Not used.
IEEE802 11b card access error 854
D Not used.
IEEE802 11b card error 855
D Not used.
IEEE802 11b card connection board error 856
D Not used.
Address book data error 870
B The address book in the hard disk is
accessed. An error is detected in
the address book data; address book
data is not read; or data is not written
into the address book.
Data corruption
Defective hard disk
Defective software
NOTE: To recover from the error, do any of the following countermeasures:
Format the address book by using SP5-832-008 (all data in the address book–
including the user codes and counters–is initialized)
Initialize the user data by using SP5-832-006 and -007 (the user codes and
counters are recovered when the main switch is turned ON).
Replace the hard disk (the user codes and counters are recovered when the m ain
switch is turned ON).
Printer error 920 D The printer program cannot be
continued. Defective hardware
Data corruption
Defective software
Net file error 925 D The management file for net files is
corrupted; net files are not normally
read.
Netfiles: Jobs to be printed from the
document server using a PC and the
DeskTopBinder software
Defective hardware
Data corruption
Defective software
Other system SCs 992 C The controller received an unknown
SC code from the engine. Contact your product specialist.
Network error 993 D The ASIC program of GW controller
cannot be continued. Defective GW controller