April, 2007 SERVICE PROGRAM TABLES

5-95

3820
Manual ProCon Execute Process Control Manually
Use this SP to execute process control manually.
3820 001 does potential control only.
3820 002 does potential control and toner density adjustment.
Note:
You must do SP3820 to enable any values you change with SP3531 (Procon
Target).
Use SP3561 to display the resuls of SP3820 execution.
001
Normal ProCon
002
Exe Density Adj [0~0/1]
3821
ProCon OK? Display Result of Process Control Execution
Use this SP to display the history of process control executions. These SP codes are
used to troubleshoot processing control. For more, see "4.2.4 Process Contro l
Troubleshooting" in Section "4. Troubleshooting".
[0~99999999/1]
001
History:Last 006
History:Last 6
002
History:Last 2 007
History:Last 7
003
History:Last 3 008
History:Last 8
004
History:Last 4 009
History:Last 9
005
History:Last 5 010
History:Last 10
3891
Set ProCon Send Set Up Sending Process Control Data to NRS Center
This feature is not presently used. (March 2005)
[0~1/1]
3900
RsetProConSP Reset All Process Control SP Codes
Do this SP to reset all process control related SP codes to their default values.