SERVICE PROGRAM TABLES August, 2006

5-126

5849 Installation Date
Displays or prints the installation date of the machine.
001 Display The “Counter Clear Day” has been changed to “Installation
Date” or “Inst. Date”.
002 Switch to Print Determines whether the installation date is printed on the
printout for the total counter.
[0~1/1]
0: No Print
1: Print
5853 Stamp Data Download
Press [Execute] to download the fixed stamp data from the machine ROM onto
the hard disk. Then these stamps can be used by the system. If this is not done,
the user will not have access to the fixed stamps (“Confidential”, “Secret”, etc.).
You must always execute this SP after replacing the HDD or after formatting the
HDD. Always switch the machine off and on after executing this SP.
5856 Remote ROM Update
When set to “1” allows reception of firmware data via the local port (IEEE 1284)
during a remote ROM update. This setting is reset to zero after the machine is
cycled off and on. Allows the technician to upgrade the firmware using a parallel
cable
[0~1/1]
0: Not allowed
1: Allowed
5857 Save Debug Log
001 On/Off (1:ON 0:OFF)
Switches on the debug log feature. The debug log cannot be captured unt il this feature
is switched on.
[0~1/1]
0: OFF
1: ON
002 Target (2: HDD 3: SD Card)
Selects the destination where the debugging information generated by the e vent
selected by SP5858 will be stored if an error is generated
[2~3 /1]
2: HDD
3: SD Card
005 Save to HDD
Specifies the decimal key number of the log to be written to the hard disk.
006 Save to SD Card
Specifies the decimal key number of the log to be written to the SD Card.
009 Copy HDD to SD Card (Latest 4 MB)
Takes the most recent 4 MB of the log written to the hard disk and copies t hem to the
SD Card.
A unique file name is generated to avoid overwriting existing file names on the SD
Card. Up to 4MB can be copied to an SD Card. 4 MB segments can be copied one b y
one to each SD Card.