Xerox 61xx manual 16. Q1213 sensor, Clearing the Q1221, Q1218, and Q1227 sensors

Models: 61xx

1 140
Download 140 pages 40.47 Kb
Page 112
Image 112
Figure 6-16. Q1213 sensor

Problem solving

Figure 6-16. Q1213 sensor

4.Brush a folded sheet of paper across the sensor to clear any obstruction.

5.Close the binder drawer and the finisher doors.

Clearing the Q1221, Q1218, and Q1227 sensors

Clearing the Q1221, Q1218, and Q1227 sensors should be performed only when directed by a Customer Support Center Representative.

1.Open the finisher front doors.

2.Locate the Q1221, Q1218, and Q1227 sensors, as shown in figure 6-17.