Chapter8: Configuring ATM Virtual Circuits
Avidia System Configuration and Management User Manual 161
Examples
::aps=> show::aps=> show 12
A screen similar to the following displays.
Information Description
Slot The slot for which the APS configuration is displayed.
Enable Whether APS is enabled or disabled for the slot.
Mode The configured APS mode Options:
autonorev (non revertive auto switch)once traffic has
switched to the protection channel it will automatically switch back
to the working channel when the system detects an error on the
protection channel and the failure on the working channel has bee n
cleared.
norev (non revertive manual)once traffic has switched to the
protection channel it will not automatically switch back to the
working channel when the failure on that channel has been cleared
(this is the default).
rev (revertive)once traffic has switched to the protection
channel, it will automatically switch back to the working channel
when the failure on the working channel has been cleared for a
user-specified amount of time.
WTR When the APS is set to rev, this parameter specifies the number of
seconds the system waits before switching traffic from the protection
channel back to the working channel after a failure on the main channel
has been cleared. The range is 300 to 720 seconds. The default is 300
seconds.
Command Which, if any, manual APS commands are in effect.
TrapEn Whether APS trap generation is enabled or disabled.
::aps=> show
Slot Enable Mode WTR Command TrapEn
12 enable(1) nonRevertiveAuto(2) 300 none enable(1)