Monitoring IDSL Alarm Status
338 Avidia System Configuration and Management User Manual
A screen similar to the following displays.
Network indicates statistics for the upstream direction, toward the network. Customer indicates
statistics for the downstream direction, toward the customer.
Information Description
Port The slot number and port number for which alarm
status is displayed.
Loss of Signal (LOS) The Loss of Signal alarm status (active or inactive). An
LOS alarm is reported when the signal is lost or when
40 consecutive ISDN frames are lost.
Hourly Errored Seconds (ES)
(Network/Customer)
The Hourly Errored Seconds alarm status (active or
inactive).
Daily Errored Seconds (ES)
(Network/Customer)
The Daily Errored Seconds alarm status (active or
inactive).
Hourly Severely Errored Seconds (SES)
(Network/Customer)
The Hourly Severely Errored Seconds alarm status
(active or inactive).
Daily Severely Errored Seconds (SES)
(Network/Customer)
The Daily Severely Errored Seconds alarm status
(active or inactive).
Last Time Change The date and time the alarm status changed.
::idsl=> alarm 5.2
***** THE IDSL ALARM STATUS TABLE FOR PORT 5.2 *****
Loss of Signal (LOS): inactive(1)
Network Hourly Errored Seconds (ES): active(2)
Network Hourly Severely Errored Seconds (SES): inactive(1)
Network Daily Errored Seconds (ES): inactive(1)
Network Daily Severely Errored Seconds (SES): inactive(1)
Customer Hourly Errored Seconds (ES): inactive(1)
Customer Hourly Severely Errored Seconds (SES): inactive(1)
Customer Daily Errored Seconds (ES): inactive(1)
Customer Daily Severely Errored Seconds (SES): inactive(1)
Last Change: Thu, Jan 01 1970 00:00:00