Chapter28: Monitoring System Alarms and Status
Avidia System Configuration and Management User Manual 555
The IDSL Alarm Status window provides the following information. The alarm thresholds for errored seconds and severely errored seconds were configured using the IDSL Alarm Configuration
Profile Table (see “Configuring IDSL Alarm Profiles” on page408). Network indicates statistics
for the upstream direction, toward the network. Customer indicates statistics for the downstream direction, toward the customer. Status Box Description
Slot
Port
Card Description
The slot number, port number and description of the
IDSL card for which alarm status is displayed.
Hourly Errored Seconds
(Network/Customer)
The Hourly Errored Seconds alarm status (Active or
Inactive).
Daily Errored Seconds
(Network/Customer)
The Daily Errored Seconds alarm status (Active or
Inactive).
Hourly Severely Errored Seconds
(Network/Customer)
The Hourly Severely Errored Seconds alarm status
(Active or Inactive).
Daily Severely Errored Seconds
(Network/Customer)
The Daily Severely Errored Seconds alarm status
(Active or Inactive).
LOS The Loss Of Signal alarm status (Active or Inactive).
An LOS alarm is reported when the signal is lost or
when 40 consecutive ISDN frames are lost.
Last Time Change The date and time the alarm status changed.