Monitoring SONET Performance
280 Avidia System Configuration and Management User Manual
Monitoring SONET Section Statistics
From the ::sonet=> prompt, type the section command in the following format then press
.
section [<port>] [-interval (<number>|all)]
Parameter
[<port>]
Specifies a particular port for which to display statistics (format slot.port). Each OC3 line
card has two SONET fiber ports, which are identified by 1a and 1b. Omitting this parameter
displays statistics for all SONET ports.
[-interval (<number>|all)
Specifies the 15-minute reporting interval for which the statistics are displayed. Typing
-interval all displays the entire 24-hour history. Omitting this parameter displays
the current status.
<number>
Type a number from 1 to 96, where 1 represents the most recent 15-minute reporting
interval and 5 represents the fifth most recent 15-minute reporting interval.
Examples
::sonet=> section 12.1a -interval 5
::sonet=> section
The following screen illustrates both section commands.
ENTER
::sonet=> section 12.1a -interval 5
Port ESs SESs SEFSs CVs Interval
12.1a 0 0 0 0 5
::sonet=> section
Port Status ESs SESs SEFSs CVs
12.1a LOF 0 0 0 0
12.1b LOF 0 0 0 0