Configuring IDSL Alarm Profiles
132 Avidia System Configuration and Management User Manual
Examples
::alarm=> show 1::alarm=> showThe following screen shows an example of both show alarm commands.
Information Description
Index The index number of the alarm profile.
Hourly ES The number of errored seconds that must be met or
exceeded on the IDSL line within an hour for a trap to
occur. The range is 0 (disable) to 255.
Hourly SES The number of severely errored seconds that must be
met or exceeded on the IDSL line within an hour for a
trap to occur. The range is 0 (disable) to 127.
Daily ES The daily ES threshold is the number of errored
seconds that must be met or exceeded on the IDSL
line within a day for a trap to occur. The range is 0
(disable) to 4095.
Daily SES The number of severely errored seconds that must be
met or exceeded on the IDSL line within a day for a trap
to occur. The range is 0 (disable) to 2047.
::alarm=> show 1
Hourly Hourly Daily Daily
Index ES SES ES SES
1 40 10 100 25
::alarm=> show
Hourly Hourly Daily Daily
Index ES SES ES SES
1 40 10 100 25
2 40 15 100 30
3 50 10 125 25