Configuring Frame Relay Links
208 Avidia System Configuration and Management User Manual
[-lmitype (LMI|ANNEXA|ANNEXD|NONE)]
The LMI (Local Management Interface) type defines a method of exchanging status
information between the customer device and the network. The options are:
LMILMI Rev-1
ANNEXAITU 0.933 Annex-A
ANNEXDANSI T1 617 Annex-D
NONEno LMI support
[-pollinterval <int>]
The poll interval value in seconds. Poll Interval is the number of seconds between LMI
status inquiry messages. The valid range is 5 to 30, with 15 as the default.
[-enqinterval <int>]
The inquiry interval value. Inquiry interval is the number of poll intervals before a full
status inquiry message is sent. The valid range is 1 to 255, with 6 as the default.
[-errthreshold <val>]
The error threshold value. Error threshold is the number of consecutive poll intervals in
which the LMI status inquiry messages are not received that are required for the link to be
declared down. The valid range is 1 to 10, with 3 as the default.
[-monevents <val>]
The monitor events value. Monitor events is the number of poll intervals in which the LMI
status inquiry messages are not received that are required for the link to be declared down.
The valid range is 1 to 10, with 4 as the default.
Example
::link=> set 5.1 -lmitype LMI -pollinterval 15 -enqinterval 6
-errthreshold 3 -monevents 5
If the LMI type is set to NONE, the poll interval, inquiry interval, error threshold,
and monitor events parameters are not used.