Configuring SDSL Frame Alarm Profiles
396 Avidia System Configuration and Management User Manual
4In the Alarm Setting UAS box, select the desired unavailable seconds alarm setting (disable,
enable).
5In the Threshold Margin box, type the desired margin threshold, in decibels.
When the margin falls below the specified threshold, the margin alarm is activated. A
typical margin threshold value is 6.
6In the Threshold ES box, type the desired errored seconds threshold.
When the number of errored seconds in the current 15-minute data collection interval
exceeds the specified threshold, the errored seconds alarm is activated. Errored seconds are
seconds during which errors occur that prevent the payload from being corrected. A typical
errored second threshold value is 17.
7In the Threshold UAS box, type the desired unavailable seconds threshold.
When the number of unavailable seconds in the current 15-minute data collection interval
exceeds the specified threshold, the UAS alarm is activated. Unavailable seconds are
seconds during which the SDSL loop is not synchronized. A typical unavailable seconds
threshold value is 60.
8Click Add to add the SDSL alarm profile.
Deleting SDSL Frame Alarm Profiles1In the SDSL Alarm Profile Table window, locate the table row that contains the SDSL alarm
profile you want to delete.
Click and if necessary to view the entire table. displays the beginning of the
table. displays the next page of the table.
2Select the Delete check box next to the row that contains the profile you want to delete. To
select the Delete check box for all rows (except the default profile, which cannot be
deleted), click Check All.
If you decide not to delete a selected row, clear the Delete check box next to the row. Click
Clear All to clear the Delete check box for all rows.
You cannot delete profiles that are assigned to ports.