Configuring SDSL Cell Alarm Profiles
122 Avidia System Configuration and Management User Manual
Adding SDSL Cell Alarm ProfilesFrom the ::alarm=> prompt, type the new command in the following format then press
to create a new SDSL cell alarm profile. The profile is automatically assigned the next
available index number in the SDSL cell alarm profile table.
new <threshLOSS> <threshLOCD> <threshSLOCD> <threshSNR>
Parameters
<threshLOSS>
The loss of signal seconds threshold. When the number of loss of signal seconds in the
current 15-minute data collection interval exceeds the specified threshold, the loss of signal
seconds alarm is activated. Loss of signal seconds are seconds during which the SDSL cell
line is incapable of transmitting or receiving data and all data is lost.
<threshLOCD>
The loss of cell delineation threshold. When the number of loss of cell delineation seconds
in the current 15-minute data collection interval exceeds the specified threshold, the loss of
cell delineation alarm is activated. Loss of cell delineation seconds are seconds in which
some cells transmitted during that second were lost.
<threshSLOCD>
The severe loss of cell delineation threshold. When the number of severe loss of cell
delineation seconds in the current 15-minute data collection interval exceeds the specified
threshold, the severe loss of cell delineation alarm is activated. During a severe loss of cell
delineation second most of the cells transmitted during that second are lost.
<threshSNR>
The signal-to-noise ratio threshold. When the signal-to-noise ratio margin drops below the
specified threshold in the current 15-minute collection interval, the signal-to-noise ratio
alarm is activated. SNR margin is a measure of signal quality indicating how much margin
can be dropped before the number of bit errors exceeds the ratio of 1x10-7 errored bits per
bits transmitted.
Example
::alarm=> new15151010
ENTER