Chapter12: Monitoring Subscriber Connections
Avidia System Configuration and Management User Manual 269
Examples
::cell=> line 18.1
::cell=> line
A screen similar to the following displays.
The following table describes the information displayed by a line command.
Information Description
Port The slot and port for which the statics are displayed.
SDSL_State The current status of the SDSL cell loop. Options:
UpThe line is up.
DownThe line is down.
HandThe line is trying to connect.
TestThe line is in test mode.
FailThe line has failed.
SNR The signal-to-noise ratio margin of the signal received in dB.
Atn The measured difference between the total signal power transmi tted by the
sending unit and the total signal power received by the receiving unit in dB.
::cell=>line 18.1
Port SDSL_State SNR Atn
18.1 down(2) 0 0
:cell=>line
Port SDSL_State SNR Atn
18.1 down(2) 0 0
18.2 down(2) 0 0
18.3 down(2) 0 0
18.4 down(2) 0 0