6-2PORT TYPES/INSTALLATION COMPATIBILITIES

Generic 1, Generic 2, CEM, or D4-channel bank). The other line-interface unit connects to the NCTE and T1 facility.

Dedicated data applications, both point-to-point and multipoint, can be connected to the CDM and inserted in selected channels. At the receive end, particular channels may be dropped from a DS1 or T1 facility by another CDM, or routed through a dedicated switch connection (DSC) as required.

TABLE 6-1.Supported Digital Facilities

DS1/DMI/ISDN-PRI Circuit-Pack Suffix Compatibility Matrix

 

Signaling

 

 

 

System 85 R2 and G2

 

 

System 75 R1 and G1

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

 

TN380_

ANN11_

ANN35_

TN555

TN767

 

Switch

TN722_

TN767

 

 

 

 

 

 

 

 

Version

 

 

(Note 1)

 

(G2 Only)

(G2 Only)

 

Version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E&M

 

V1-V4,G2

 

B, C, D

B, C, D, E

N/A

N/A

all

 

V2,V3,G1

all

all

 

Signaling

 

 

 

(Note 2)

(Notes 2&3)

 

 

 

 

 

 

 

 

Ground Start

 

V3,V4,G2

 

C, D

C, D, E

N/A

N/A

all

 

G1

N/A

all

(CO,

FX, WATS,

RA,

 

 

 

 

 

 

 

 

 

 

(Note 4)

 

Plus DID)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loop Start

 

V3,V4,G2

 

C, D

C, D, E

N/A

N/A

all

 

G1

N/A

all

(CO,

FX, WATS,

RA)

 

 

 

 

 

 

 

 

 

 

(Note 4)

OPS Line (Note 5)

V3,V4,G2

 

C, D

C, D, E

N/A

N/A

all

 

G1

N/A

all

DMI-BOS (Note 3)

V3,V4,G2

 

C, D

D, E

N/A

N/A

all

 

V2,V3,G1

B

all

 

 

 

 

 

 

 

 

 

 

 

 

DSC (analog data)

V3,V4,G2

 

C, D

C, D, E

all

N/A

all

 

N/A

N/A

N/A

 

 

 

(Note 6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DMI-MOS and ISDN

V4,G2

 

D

N/A

all

N/A

all

 

G1

N/A

all

 

(Note 7)

 

 

 

 

 

 

(Note 8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proprietary

 

V1-V4,G2

 

B,C,D

C,D,E

N/A

N/A

all

 

V2,V3,G1

all

all

 

 

 

 

 

(Note 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1.The ANN11E and ANN11C have similar functions with one exception: the ANN11E supports the DMI-BOS 24th-channel-signaling format and the ANN11C does not. The DMI-BOS format was added in addition to the proprietary 24th-channel and robbed-bit formats supported by ANN11C. The applications of these formats are summarized below in a feature comparison. The ANN11C and ANN11E are compatible with respect to all other options not listed in this table (including robbed-bit (RB) signaling, D4/ESF framing, and ZCS/B8ZS line coding).

SIG. TYPE ANN11 REQ

APPLICATIONS SUPPORTED

Robbed Bit C or E

Voice-grade tie, DID, & CO trunks, OPS lines, connections to D4-channel banks, DSCs, ACCUNET®

 

switched digital

 

 

Proprietary C or E

AVD-tie trunks between System 85s and between System 85 and System 75

24th Chan.

 

 

 

DMI-BOS E

Proprietary 24th-channel format applications plus connections to any endpoint conforming to the

24th Chan.

“AT&T Digital Multiplexed Interface Technical Specification”. Examples include 3B5 hosts, HP3000

 

hosts, and IBM® IDNX multiplexers. These endpoints are called “DMI-BOS endpoints” in these

 

notes. Other vendor equipment is certified by AT&T for this connectivity. Certified equipment

 

requires an ANN11E at the System 85 end.

 

 

Page 124
Image 124
AT&T DS1/DMi/ISDN-PRI manual 2PORT TYPES/INSTALLATION Compatibilities, FX, Wats, Dmi-Bos E