AT&T
Page
Contents
DS1 Transmission and Cabling
LOSS-PLAN Implementation and Provisioning
Digital Loss Plan
Synchronization of Digital Facilities
Need for Synchronization Synchronization Hierarchy
Port TYPES/INSTALLATION Compatibilities
Administration Options and Requirements
Generic
System 75 R1V2 and R1V3
Maintenance and Alarms
Administrative Procedure Summary
Procedure
GL-1
AB-1
Glossary
Index
List of Figures
Contents
Xiv Contents
Procedure 012 Word 1 Name Database Generic
Figure A-1 DS1 Circuit Pack Screen
List of Tables
Bccos
User-to-User IE Opcodes
About this Document
Purpose
Prerequisite Skills and Knowledge
Intended Audiences
HOW this Document is Organized
Abbreviations Glossary Index
Appendixes
About this Document
Trademarks and Service Marks
HOW to USE this Document
Related Sources
HOW to Make Comments about this Document
AT&T
Xxiv about this Document
Fundamentals of DS1 Signals
Introduction
2INTRODUCTION
Layer
Introduction
Megacom
4INTRODUCTION
Introduction
6INTRODUCTION
Channels
Voice Voice-grade data Digital data
8INTRODUCTION
Channel Backup Generic
Channels
D4 Framing
Circuit-Switched Versus Packet-Switched Channels
Framing Formats
10INTRODUCTION
D4 Framing
ESF Framing
Data Link Signal Frame Sync Pattern
Bits Robbed BIT Optional
DS1 Signal, Framing Format, and ESF Superframe 24 Frames
24th-Channel Signaling
Signaling Types
Robbed-Bit Signaling
14INTRODUCTION
ESF
Signaling Superframe
Superframe Frame No
Alternate Mark Inversion
Line-Coding Formats
16INTRODUCTION
1s-Density Requirement
Zero Code Suppression and Bipolar with 8 Zero Substitution
Unrestricted or Clear Channel
Restricted Channel
18INTRODUCTION
Introduction Uncoded BIT Stream Pulse
Differences Between ZCS and B8ZS
Violations Based on Polarity Last 1 Transmitted
Communication Protocols and 1s-Density Requirement
Bipolar Violations
20INTRODUCTION
Data
DMI
Alternate Voice/Data AVD Trunks
Common-Channel Signaling
Important Concepts
22INTRODUCTION
Bearer Capability BC
System 85 R2V4
Generic
24INTRODUCTION
Isdn Call Processing
Switch Parameter Default Value
Bccos
Outgoing Calls
Summary
Incoming Calls
26INTRODUCTION
Introduction
System 85 R2V4/Generic 2 CBC Implementation
CBC Service Selection
28INTRODUCTION
Generic 1 Implementation
Networking Restrictions and ISDN-PRI Limitations
30INTRODUCTION
Introduction
32INTRODUCTION
Network Difficulties
Hyperactivity
2NETWORK Connections and Configurations
Glare
DS1/DMI PRIVATE-NETWORK Connections
Network Connections and Configurations
Host Computer to Another System
4NETWORK Connections and Configurations
Other Vendor Digital Switch to Another System
IBM Idnx Multiplexer to Another System
Analog Switch to Another System
OPS to Another System Via a D4-Channel Bank
4ESS to Another System Special-Access Connection
DS1/DMI PUBLIC-NETWORK Connections
Synchronization
Screening Intra-LATA Calls
5ESS to Another System
Dacs to Another System
8NETWORK Connections and Configurations
Analog CO to Another System Via a D4-Channel Bank
DS1/DMI TERMINAL-EQUIPMENT Connections
CDM
10NETWORK Connections and Configurations
CEM to a BCM32000
Network Connections and Configurations
ISDN-PRI PRIVATE-NETWORK Connections
12NETWORK Connections and Configurations
System 85 R2 to a System 85 R2V4, Generic 1, or Generic
ISDN-PRI PUBLIC-NETWORK Connections
System 85 R2V4, Generic 1, and Generic 2 to a 4ESS
Codeset
Backup D-Channel
14NETWORK Connections and Configurations
User-to-User Information transfer
System 85 R2V4, Generic 1, or Generic 2 to a Dacs
Network Specific Facility
Synchronization
System 85 or Generic 2 ISDN-PRI to a 5ESS
16NETWORK Connections and Configurations
DS1 Transmission and Cabling
Network Channel Terminating Equipment Ncte
Metallic Cabling Options
DSX-1 Distance Limitations
2DS1 Transmission and Cabling
Direct Under 1310 Feet
On-Premises Cabling
DS1 Transmission and Cabling
Greater Than 4310 Feet
Between 1310 and 4310 Feet
4DS1 Transmission and Cabling
Maximum DSX-1 DS1
Off-Premises Cabling
Maximum FT or Less
Maximum Distance of 4311 or More
DSX-1 T E DS1
Nonmetallic Cabling Options
6DS1 Transmission and Cabling
Maximum
CEM and CDM Cabling Configurations
DS1/DMI DSX-1
ANY DS1 DSX-1 Channel Bank Transmission
CDM DSX-1 Or D4 Channel
Media Dedicated Channel Units Applications CDM only
AWG Abam & 24 AWG PDS
Line Equalizer and Compensation Settings
System 85 Traditional Modules
OFF
10DS1 Transmission and Cabling
Digital Loss Plan
Generic
LOSS-PLAN Implementation and Provisioning
2THE Digital Loss Plan
Encode Loss-Plan Function ANSI/EIA/TIA-464-A-1989 Designator
Digital Loss Plan
Loss
Loss plan
Digital conn
PORT-TO-PORT Loss Values
Transmit Receive Direction
Analog Facility DS1/DMI Digital Switch Channel Bank N K ONS
A L
Tie Trunk Ports
DS1/DMI/ISDN-PRI Port Losses
Terminating a DS1 AT a Channel Bank
CO did Trunk Ports
OPS Ports
8THE Digital Loss Plan
Synchronization of Digital Facilities
Need for Synchronization
Channel Analog Bank Receive
2SYNCHRONIZATION of Digital Facilities
Transmit
Bank Transmit Digital BIT Stream
Synchronization Hierarchy
Synchronization of Digital Facilities
4SYNCHRONIZATION of Digital Facilities
Page
6SYNCHRONIZATION of Digital Facilities
System 85 and Generic 2 Synchronization Architecture
Page
System 85 and Generic 2 Synchronization Software Operation
Blue YEL Good LOS Misf
Primary Secondary Reference Indicators
Indicators
RED
System 75 and Generic 1 Synchronization Architecture
System 75 and Generic 1 Synchronization Software Operation
Criteria for Switching to the Secondary Reference
Criteria for Switching Back to the Primary Reference
External Synchronization Clock
14SYNCHRONIZATION of Digital Facilities
Synchronization of Digital Facilities
16SYNCHRONIZATION of Digital Facilities
External-Clock Interface
Network Synchronization and Engineering
Selecting a Timing Source for the Switch
18SYNCHRONIZATION of Digital Facilities
Internal Reference Selection Rules
Rule
20SYNCHRONIZATION of Digital Facilities
Digital Transmission Facilities Primary Frequency Reference
13.Proper Use of Backup Facilities
Page
15.Optimal Diverse Routing
16.Less Than Optimal Diverse Routing
17.Excessive Cascading
19.Excessive Synchronization from One Node
26SYNCHRONIZATION of Digital Facilities
External-Reference Selection Rules
Rules 2 Through
Fact
Availability of Synchronization Sources
Misconception
28SYNCHRONIZATION of Digital Facilities
USE of Generic 2 AS a System Clock Reference
Line-Only Mode DS1/DMI-BOS ANN11 or TN767
Conclusions on Synchronization
ISDN-PRI Trunk Facilities ANN35 or TN767 with TN755
USE of Generic 1 AS a System Clock Reference
Line+Trunk Mode DS1/DMI-BOS ANN35 or TN767 with TN555
DMI-MOS ANN35 or TN767 with TN755
Trunk-Mode ISDN-PRI TN767
Line-Only Mode DS1/DMI-BOS TN767
Trunk-Mode DS1/DMI-MOS TN767
32SYNCHRONIZATION of Digital Facilities
Port TYPES/INSTALLATION Compatibilities
FX, Wats
2PORT TYPES/INSTALLATION Compatibilities
DMI-BOS E
Port TYPES/INSTALLATION Compatibilities
Generic 1 DS1/DMI-BOS
Operating Mode
4PORT TYPES/INSTALLATION Compatibilities
Supported Port Types
Generic 1 ISDN-PRI
Line-Only Mode
DMI Trunks
System 85 DS1, Traditional Modules ANN11
Line+Trunk Mode
6PORT TYPES/INSTALLATION Compatibilities
Port TYPES/INSTALLATION Compatibilities
OPS Other Circuit Packs OPS PORTS/CARRIER Slot
Others
Port TYPES/INSTALLATION Compatibilities Carrier Slots P T Y
Line+Trunk Mode Port Grouping Rules
10PORT TYPES/INSTALLATION Compatibilities
Did Trunk
DMI-BOS Trunks
Ground-Start CO Trunk
Of-Premises Stations
12PORT TYPES/INSTALLATION Compatibilities
Loop-Start CO Trunk
Transparent Ports
System 85 DS1 or DMI-MOS, Traditional Modules ANN35
14PORT TYPES/INSTALLATION Compatibilities
Port Grouping Rules
Administration Options and Requirements
2ADMINISTRATION Options and Requirements
System 85 R2V1 Through R2V4
Procedure 275 Word 4 Isdn Service Enable/Disable
Administration Options and Requirements System
Field
4ADMINISTRATION Options and Requirements System
Procedure 276 Word 1 Other Feature Groups
Procedure 250 Word 1 DS1 Carrier Designation
Display only
Position
V1-V4
Module Control
Procedure 260 Word 1 DS1/DMI/ISDN-PRI Physical Interface
Slot numbers 0, 5, 13, or 18 for line-only operation
Service or Facility Options
Can be assigned
V1-V2
Voice/data AVD
V3-V4
10ADMINISTRATION Options and Requirements System
Criteria for Switching to the Secondary Facility
Criteria for Switching Back to the Primary Facility
12ADMINISTRATION Options and Requirements System
DS1/OPS Related Translations
14ADMINISTRATION Options and Requirements System
DS1 Channel Slot/Circuit
V4 Only
DS1/DMI-BOS applications should be administered with a
Supported. Therefore, option one is not applicable
Fields
Procedure 262 Word 1 Isdn Board Parameters
16ADMINISTRATION Options and Requirements System
PRI Parameters
Field
Procedure 354 Word 3 NPA-NXX Digits Assignment
Procedure 000 Word 4 NPA-NXX Index Designator
Enhanced Mode Procedure 354, Word NPA-NXX Assignment
20ADMINISTRATION Options and Requirements System
Range of 1 through
22ADMINISTRATION Options and Requirements System
Field
Enhanced Mode Procedure 100, Word Trunk Group Translation
24ADMINISTRATION Options and Requirements System
Dial Access CODE/TRUNK ID Code
Isdn TIE
Trunk Description Type
Did
Wats
Procedure 100 Word 2 Trunk Group Data Translations
Administration Options and REQUIREMENT’S System
Data Rate
Procedure 100 Word 3 Isdn Trunk Group Signaling Options
Modem Pooling
Sychronous Duplex
28ADMINISTRATION Options and Requirements System
Field
Isdn network features is desired
Field 1 Field
32ADMINISTRATION Options and Requirements System
Fields Fields 9-11 Field
This field is ignored by Isdn software
34ADMINISTRATION Options and Requirements System
Procedure 116 Word 1 DS1/DMI/ISDN-PRI Trunk Assignments
36ADMINISTRATION Options and Requirements System
DS1/ISDN-PRI Administration Channel Versus Trunk Assignments
Procedure 012 Word 1 Name Database
38ADMINISTRATION Options and Requirements System
Through 99999, for extension and directory numbers
Procedure 012 Word 2 Name Database
Enhanced Mode Procedure 012, Word Name Database Entry
Procedure 012 Word 3 Name Database
Charater Encodes
42ADMINISTRATION Options and Requirements System
Enhanced Mode Procedure 012, Word Name Database Compaction
Enhanced Mode Procedure 309, Word ARS Route Tables
IXC Isdn
44ADMINISTRATION Options and Requirements System
Bearer Capability
Network Feature Value Trunk Type
Network Service/Feature Options, shows the relationships
Network Service or
Isdn
46ADMINISTRATION Options and Requirements System
AAR System 85 R2V4, depicts the procedure
Enhanced Mode Procedure 321, Word AAR Route Tables
Bearer Capability
NSF
Procedure Word Field
NSF IXC
TNS
23. Procedure
TTL Telephone Digits
Terminating Test Line Telephone Digits
Generic
Administration Options and Requirements Generic
Maximum Preemption Level Administrable Alarms
Attendant Release Loop Operation
52ADMINISTRATION Options and Requirements Generic
SNC
Procedure 250 Word 1 SC/DS1 Carrier Designation
54ADMINISTRATION Options and Requirements Generic
Field Fields
SC Information Connected to CC0 ON-LINE Enter command
Equipment Traditional Universal Parameter Module
ISDN-PRI
That
Zero Code Suppression ZCS
Criteria for Switching to the Secondary
Criteria for Switching Back to the Primary
Field
62ADMINISTRATION Options and Requirements Generic
Field
Distance to Midpoint Compensation Or Endpoint FT
133 to 90 to 266 to 180 to 399 to 270 to 532 to 360 to
BRI Only
PRI and BRI Layer 2 Parameters
Depending on the particular facility
Procedure 262 Word 2 ISDN-PRI D-Channel Backup
NFAS-PRI Only
Backup Channel Equipment Location
68ADMINISTRATION Options and Requirements Generic
Primary D-CHANNEL Equipment Location
Procedure 262 Word 3 ISDN-PRI Codeset Map Assignments
Performance
Mapped from CODESET/INFORMATION Element
Enhanced Mode Procedure 280, Word Isdn Codeset Mapping
Mapped to CODESET/INFORMATION Element
Field Field 6 Field IE Name Codeset
NPA
Enhanced Mode Procedure 354, Word
NXX
34.Procedure 000 Word 4 NPA-NXX Index Designator
74ADMINISTRATION Options and Requirements Generic
LDN
Enhanced Mode Procedure 210, Word
NPA-NXX
Procedure 014 Word 1 Bccos Routing Options
Differences Between System 85 R2V4 and Generic
COS Default Capabilities
Call Types and Action Taken
Procedure 014 Word 2 Bccos Data Options
78ADMINISTRATION Options and Requirements Generic
Or is not 0 supported
38.Procedure 010 Word 4 Terminal COS Restrictions Generic
80ADMINISTRATION Options and Requirements Generic
Field
82ADMINISTRATION Options and Requirements Generic
Enhanced Mode Procedure 100, Word
DMI
Isdn
84ADMINISTRATION Options and Requirements Generic
40. Procedure
86ADMINISTRATION Options and Requirements Generic
Not applicable For
Whether access to other Isdn network features is desired
Assigns whether the trunk group has 1 or does not have
Procedure 103 Word 1 Network Trunk Group Translations
AAR/ARS
92ADMINISTRATION Options and Requirements Generic
Channel Versus Trunk Assignments
DS1 Channel Slot/Circuit
45.Procedure 012 Word 1 Name Database Generic
94ADMINISTRATION Options and Requirements Generic
From 1 to
96ADMINISTRATION Options and Requirements Generic
Character Encodes
47.Procedure 012 Word 3 Name Database Generic Field
Isdn Network Definition
98ADMINISTRATION Options and Requirements Generic
Enhanced Mode Procedure 279, Word NETWORK-SPECIFIC Facility
Parameters
Name
Network Parameterized Feature Facility
11. Network
Coding Value Binary
Procedure 309 Word 1 ARS Route Tables
100ADMINISTRATION Options and Requirements Generic
Procedure 309 Word 5 ARS-ISDN Bccos
Enhanced Mode Procedure 309, Word
Procedure 321 Word 1 AAR Tables Generic
Services/Network Features, for the appropriate encode
102ADMINISTRATION Options and Requirements Generic
Enhanced Mode Procedure 321, Word
Procedure 321 Word 5 AAR-ISDN and Other Feature Parameters
104ADMINISTRATION Options and Requirements Generic
53.Procedure 107 Word 1 Atms TTL Assignment System 85 R2V4
Procedure 108 Word 1 Isdn Trunk Group TTL Number Digits
106ADMINISTRATION Options and Requirements Generic
System 75 R1V2 and R1V3
Service/Facility Options
DMI-BOS? Maintenance Parameters
DS1 Circuit Pack
108ADMINISTRATION Options and Requirements System
Compensation Value Distance Feet
109
Remote
Slip
Detection
Loop
Synchronization Plan
DS1 Circuit Packs
112ADMINISTRATION Options and Requirements System
Trunk Group/Trunk Group Members
Name
Delay
Port
Mode
Call
114ADMINISTRATION Options and Requirements System
ACA
AAR/ARS
60.DS1 Circuit Pack Screen, Common-Channel Signaling
116ADMINISTRATION Options and Requirements Generic
Location
Line
118ADINISTRATION Options and Requirements Generic
Interface
120ADMINISTRATION Options and Requirements Generic
STT
Trunk Group/Trunk Group Members DS1 Trunk Applications
Call COR
DTT
Avd or data
122ADMINISTRATION Options and Requirements Generic
BCC
In/out
Trunk Group ACA
PBX ID
Night
With auto Mode
Processor Interface Data Module ISDN-PRI Applications
Channel
Data Extension
Physical
Processor Channel Assignments ISDN-PRI Applications
Link
Proc Chan
Appl
Chan Priority
DTE/DCE
Trunking Considerations ISDN-PRI Applications
128ADMINISTRATION Options and Requirements Generic
Advantages of CBC Trunking
Network Facilities ISDN-PRI Applications
Feature
Either a feature 0, or service
NETWORK-FACILITIES
Trunk Group ISDN-PRI Trunk Applications
Coding
COR TAC
Service Type
Dial Access
Service
Options access, tie
Max
Send
Display/TCM
Message Size
SID?
Trunk Features
SID/ANI
134ADMINISTRATION Options and Requirements Generic
Application Example #1
Del
Application Example #2
SID/ANI
Insert
Per Call
Case
Application for Case 2 being selected
Application for Case 1 being selected most restrictive
Application for Case 3 being selected
138ADMINISTRATION Options and Requirements Generic
Application for Case 4 being selected
Trunk Group Usage Allocation ISDN-PRI Applications
Applications for Cases
Example Screen Entries for Cases
PBX
Allocation
140ADMINISTRATION Options and Requirements Generic
Usage
Plan
Min# Chan Max# Chan
An Example Application for Usage Allocation Plans
Number Scheduled
142ADMINISTRATION Options and Requirements Generic
Fixed
CBC Trunk Group Usage Allocation Plan Assignment Schedule
Trunk Group Member Assignments ISDN-PRI Trunk Applications
75.Trunk Group Screen, Page 5 ISDN-PRI
SID Prefix Table ISDN-PRI Applications
144ADMINISTRATION Options and Requirements Generic
Name Night
SID Prefix
SID Prefix
Ext Code
An Example Application that uses SID
146ADMINISTRATION Options and Requirements Generic
Routing Patterns ISDN-PRI Applications
Grp No
Pattern
Number
FRL
Digits
148ADMINISTRATION Options and Requirements Generic
No. Del
Inserted
Band
Hunt Group ISDN-PRI Applications
Hunt Group
150ADMINISTRATION Options and Requirements Generic
Terminating Extension Group ISDN-PRI Applications
ACD?
Terminating Extension Group
152ADMINISTRATION Options and Requirements Generic
Generic 1 and Generic 2 ISDN-PRI Maintenance Philosophy
Generic 2 Maintenance Capabilities and Concerns
Generic 2 Maintenance Procedures
2MAINTENANCE and Alarms
Maintenance and Alarms
4MAINTENANCE and Alarms
Summary of Generic 2 Maintenance Capabilities
Generic 1 Maintenance Procedures
Generic 1 Maintenance Capabilities and Concerns
6MAINTENANCE and Alarms
Circuit Pack Alarms
Summary of Generic 1 Maintenance Capabilities
Alarms
Yellow LED
LFA Alarm
Facility Alarms
Excessive Misframe and CRC Errors
8MAINTENANCE and Alarms
Remote Frame Alarm
Loss of Signal Alarm
Framing Mode Alarm Type Conversion
Blue Alarm
Major and Minor Alarms
10MAINTENANCE and Alarms
Administration Requirements
Megacom COR
2ADMINISTRATION Requirements
PBX ID ACA
Administration Requirements
4ADMINISTRATION Requirements
Figure A-5.Trunk Group Screen, Page 1 SDN
DCS? PBX ID
6ADMINISTRATION Requirements
Facilities, for details
TRANSLATIONS-BASED Problems
Dacs
2SAMPLE Installation and Maintenance Problems
Transmission Facility
Sample Installation and Maintenance Problems
Trunks and Trunk Groups
4SAMPLE Installation and Maintenance Problems
Type
System
CDMs
CEMs
DS1 or DMI
6SAMPLE Installation and Maintenance Problems
Sample Installation Maintenance Problems
D4-Channel Banks
SYNCHRONIZATION-RELATED Problems
8SAMPLE Installation and Maintenance Problems
Loss of or No Synchronization
Leavenworth Loop
D4 Synchronization Problems
Figure B-10.Leavenworth Loop on the Primary Reference
Sample Installation and Maintenance Problems
12SAMPLE Installation and Maintenance Problems
Digital CO Synchronization Problems
Dacs
Typical Physical Interface Connection Problems
Figure B-15.Synchronization from Dacs Node
14SAMPLE Installation and Maintenance Problems
Initial System 85 DS1 or DMI Pinout for 50-PIN Connector
C6C To WIRE-LUGS
Installation Maintenance Problems
CABLE/CONNECTORS Initial or OLD PDS Compatible System
System Intracabinet
16SAMPLE Installation and Maintenance Problems
Specific Cabling Options
18SAMPLE Installation and Maintenance Problems
Permitted Cabling Combinations
Permitted Cabling Combinations Using PDS
Using cable GR-380
20SAMPLE Installation and Maintenance Problems
Permitted Cabling Combinations Using PDS
22SAMPLE Installation and Maintenance Problems
Procedure 000 Word 3 Generic 2 Only
Voice
Mode Voice Grade Data Unknown Digital Analog Mode 3/2
2ADMINISTRATIVE Procedure Summary
Administrative Procedure Summary
Procedure 000 Word 4 System 85 R2V4 & Generic
Procedure 010 Word 4 System 85 R2V4 & Generic
Isdn Routing Parameters System 85 R2V4 & Generic
BC System 85 R2V4 Only
4ADMINISTRATIVE Procedure Summary
Voice or Voice Grade Data
Procedure 012 System 85 R2V4 & Generic
Procedure 100 Word 1 System 85 R2V4 & Generic
6ADMINSTRATIVE Procedure Summary
Procedure 100 Word 2 Generic 2 Only
Rules for Trunk Type 120 System 85 R2V4 & Generic
Procedure
Procedure 100 Word 3 System 85 R2V4 & Generic
TCM
Called-Party Number IE System 85 R2V4 & Generic
Procedure 107 Word 1 System 85 R2V4 & Generic
8ADMINISTRATIVE Procedure Summary
For international calls that is, a dial Calls For ARS calls
Procedure 210 Word 2 System 85 R2V4 & Generic
Procedure 108 Word 1 System 85 R2V4 & Generic
Procedure 116 Word 1 System 85 R2V4 & Generic
Procedure 260 Word 1 System 85 R2V4 & Generic
10ADMINISTRATIVE Procedure Summary
Procedure 279 Word 1 Generic 2 Only
Procedure 262 Word 3 Generic 2 Only
Procedure 275 Word 4 System 85 R2V4 & Generic
Procedure 280 Word 1 Generic 2 Only
Information Element IE Name R2V4
12ADMINISTRATIVE Procedure Summary
IE Opcode Value
Information Element IE Name Opcode Value
Field 5, Network Service Value
Procedure 309 Word 5 System 85 R2V4 & Generic
Field 4, Isdn Trunk Type
Through 288 Outwats Band NSFs SDN NSF
14ADMINISTRATIVE Procedure Summary
NSF IE System 85 R2V4
Megacom NSF
Wats NSF Accunet via encode
NSF IE Generic
BC System 85 R2V4 and Generic
16ADMINISTRATIVE Procedure Summary
Fields 6-10 System 85 R2V4
Procedure 354 Word 3 System 85 R2V4 & Generic
Procedure 321 Word 5 System 85 R2V4 & Generic
Field 6 Generic
Procedure 420 System 85 R2V4 & Generic
18ADMINISTRATIVE Procedure Summary
Administrative Procedure Summary
20ADMINISTRATIVE Procedure Summary
Trunk Type and Signaling Type Compatibility Tables
Trunk/Signaling Cross-references
2TRUNK Type and Signaling Type Compatibility Tables
Aplt
Did
Trunk Type and Signaling Type Compatibility Tables
Wats
TIE
CAS
MAIN/SAT
NDM-I
ISDN/PRI
EQU
6TRUNK Type and Signaling Type Compatibility Tables
Trunk
R2V4 G2 Equiv Type Sig. Type
Trunk Type and Signaling Type Compatibility Tables
8TRUNK Type and Signaling Type Compatibility Tables
ANN11
S BC BCC Bccos bps
AAR F T C Afrl Aiod ALU ANI ARS Autovon AVD AWG
CBC Ccitt CCR Ccsa CDM CEM COR COS CRC CSU
Dacs dB
AB-2ABBREVIATIONS
Abbreviations AB-3
AB-4ABBREVIATIONS
Adftc Afrl Aiod
Accunet
Megacom
Tandem
Data transmission
GL-2GLOSSARY
AWG
B8ZS
Bit error rate Burstiness
Binary service
Parameterized service format
Ports, packet switching,
See network channel-terminating equipment
Glossary GL-5
Q.931
Cross coupling
Unrestricted digital data
See cyclic redundancy check
DTE
Dnis
DMI-MOS
DS1
ETN
GL-9
EIA
Epscs
GRS
Hdlc
Inads
Clock reference
See Integrated Services Digital Network
Isdn network- See Isdn network identifier. service value
GL-12GLOSSARY
Station identification number
Loss of signal
Isdn SID-ANI Lata LFA
See loss of frame alignment
Mpdm
Ncte
Network primary rate interface
OPS OPX
Digital Network primary rate interface
Glossary GL-15
PCM PDM PDS
PAD
PAM PC/PBX
PRI
PAM
PCM
SDN
Robbed-bit signaling
See remote frame alarm See Remote Group
See Software Defined Network
SS7
See time-multiplexed switch
Switch TMS
Multiplexed switch
Transport mode
ZCS
Zero code
Equal 7-43,7-47,7-101,7-103ISDN
Network 7-84,7-88nodal services
Accunet 6-3,C-16code
Adftc
Bccos 1-24,C-1
AVD 1-22,7-9
BC 1-22,C-16 BC code 7-23,7-81
Violation 1-18,1-20,3-3
9bank D4 1-1,2-5D-type1-1
Ccitt
CEM
9delta
CRC 1-12,1-14CRV CSU xix, 1-20,3-2customer
COR 7-112,7-125,A-2
DCE 1-21,7-127D-channel
I -Contd BOS-Contd
NPA-NXX7-28,7-72
BOS
Index IN-5
DTE 2-18
IN-6 Index
DS1- Contd
EIA
FXS
D4 1-10,2-5,2-7
Index IN-7
Lapd 1-3,7-17LATA 2-7layer 1 1-3layer 2
IN-8 Index
LEC
CDM
Misframe 1-11,1-14MO
Voice 1-23,7-33voice-grade data 1-23,1-24ZCS
Index IN-9
Ncte
IN-10 Index
NPA-NNX C-17
PCM 1-8,5-1PCM data
OPS
Ports 4-7,6-6
Channel1-5,1-9,7-57facility 7-11,7-59
RNX 1-27robbed-bit signaling
9sources
SS7 7-30,7-88
Index IN-13
CEM 2-10terminating
IN-14 Index
TMS
Members 7-35,7-92Generic 1
CO 2-8,7-13combination tie 2-5,6-4DID 6-11,7-13
FX 2-8,7-13ground-start CO 6-11group
108
IN-16 Index