A. ADMINISTRATION REQUIREMENTS

The following screens detail System 75 (R1V2 and R1V3) special-access administration requirements for implementing a Software Defined Network (SDN), MEGACOM® service, MEGACOM 800 service, and MEGACOM 800 dialed-number identification service (DNIS) connections to a 4ESS configured with 4e9 generic software. All screens are shown with their required or suggested field entries.

NOTE: For System 75, ACCUNET® switched digital service is available only as a special development charge.

 

 

DS1 CIRCUIT

PACK

Page 1 of 1

Location: (slot

location)

 

Name: (anything)

Line Compensation: ?

Zero

Code Suppression: zcs

Framing Mode:

D4

 

Signaling Mode: Robbed-Bit

DMI-BOS?

y

 

 

 

 

 

MAINTENANCE PARAMETERS

 

Slip Detection?

y

Remote

Loop-Around

Test? n

Figure A-1.DS1 Circuit Pack Screen