SAMPLE INSTALLATION AND MAINTENANCE PROBLEMS

B-19

 

 

 

 

 

 

Permitted Cabling Combinations Using PDS

Using cable GR-380:

NOTE: When using PDS wiring, the easiest approach is to connect the port cabinets at each end to a cross-connect field (XCF) using GR-380 cables.

With this arrangement, it is not necessary to determine the group number of the intracabinet cable.

ANN11D/E [335-337] GR-380 XCF PDSXCF ANN11D/E [335-337] GR-380 XCF PDSXCF ANN11D/E [367-369] GR-380 XCF PDSXCF

GR-380 GR-380 GR-380

[335-337] ANN11D/E

[367-369] ANN11D/E

[367-369] ANN11D/E

When at least one end does not use the GR-380 cable, the following combinations will work.

ANN11D/E [335-337]GR-380 XCFPDSXCF300[367-369] ANN11D/E ANN11D/E [335-337]GR-380 XCFPDSXCF357[335-337] ANN11D/E ANN11D/E [335-337]GR-380 XCFPDSXCF370[367-369] ANN11D/E ANN11D/E [367-369]GR-380 XCFPDSXCF300[367-369] ANN11D/E ANN11D/E [367-369]GR-380 XCFPDSXCF357[335-337] ANN11D/E ANN11D/E [367-369]GR-380 XCFPDSXCF370[367-369] ANN11D/E

Using old cable groups:

ANN11D/E [335-337] 357XCFPDS XCF 357 [335-337] ANN11D/E

Using new cable groups:

ANN11D/E [367-369] 300XCF PDSXCF300 [367-369] ANN11D/E

ANN11D/E [367-369] 300XCF PDSXCF370 [367-369] ANN11D/E

ANN11D/E [367-369]370XCF PDSXCF370 [367-369] ANN11D/E

Using a mix of old and new cable groups:

ANN11D/E [335-337] 357XCF PDSXCF 300[367-369] ANN11D/E

ANN11D/E [335-337] 357XCF PDSXCF 370[367-369] ANN11D/E

Page 323
Image 323
AT&T DS1/DMi/ISDN-PRI manual Permitted Cabling Combinations Using PDS, Using cable GR-380