ADMINISTRATION OPTIONS AND REQUIREMENTS — GENERIC 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field 18

Loop length refers to the total cable distance between the switch and the NCTE,

 

CDM, BCM32000, DSX-1 cross-connect, and T1 office repeater. Traditional

 

modules may contain the ANN11 and/or ANN35 circuit packs. Both circuit packs

 

contain DIP switches for setting the compensation value, refer to table 3-1,System

 

85 Traditional Module Equalizer Settings (Metallic Cable). Therefore,

software

 

administration is not applicable and the (–)should be administered for traditional

 

modules.

 

 

 

 

 

 

 

Universal modules may contain the TN767 circuit pack. Line compensation value

 

be administered in software. Table 7-7, TN767 Compensation Values,

identifies the

 

appropriate administration encode for distance intervals of 133 feet up to a

 

maximum distance of 655 feet.

 

 

 

 

 

 

 

 

 

TABLE 7-7.TN767 Compensation

Values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Distance to Midpoint

 

 

Compensation

 

 

 

 

 

or Endpoint (FT)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22 AWG ABAM & 24 AWG PDS

 

26 AWG PDS

 

 

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 to 133

 

0 to 90

 

 

0

 

 

 

 

 

133 to 266

 

90 to 180

 

 

1

 

 

 

 

 

266 to 399

 

180 to 270

 

 

2

 

 

 

 

 

399 to 532

 

270 to 360

 

 

3

 

 

 

 

 

532 to 665

 

360 to 450

 

 

4

 

 

 

 

 

NOTE: Compensation values assume 22-gauge ABAM or 24-gauge PDS cables. Two switches

 

 

 

 

 

(colocated) can be up to 1310 feet apart with maximum compensation on both systems. If 26-gauge

 

 

 

 

PDS cables are used, distances are reduced as assigned.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The T1 office repeaters or T1 line repeaters can be used when the on-premises

 

distance limitation is exceeded. A T1 office repeater is required at each end of the

 

connection to provide an interconnection range of up to 3000 feet. Each repeater

 

only provides regeneration for the receive direction. The T1 line repeaters can be

 

used to accommodate distances up to 6000 feet between switches. The T1 line

 

repeaters can be used in tandem to accommodate greater distances.

 

 

 

Field 19

Field encodes and their descriptions are:

 

 

 

 

 

 

(Dash) required option for all traditional modules. It is also required for all ISDN-PRI links provided with universal modules.

0 Preferred for DS1 service provided with universal modules (shows that a DS1 provides standard DMI-BOS).

1Assigns that the DS1 provides the AT&T proprietary method of signaling on the 24th channel. This option is required when connection to System 75 that still has the TN722 circuit packs.

NOTE: When connecting to a TN722B or ANN11 circuit pack, the recommended option is (0).

Page 200
Image 200
AT&T DS1/DMi/ISDN-PRI manual Distance to Midpoint Compensation Or Endpoint FT