Blue Coat Systems SGOS Version 5.2.2 manual Managing SG Appliance Systems, Troubleshooting Tip

Models: Blue Coat Systems SG Appliance SGOS Version 5.2.2

1 108
Download 108 pages 21.03 Kb
Page 40
Image 40
Managing SG Appliance Systems

Volume 9: Managing the Blue Coat SG Appliance

Troubleshooting Tip

If the SG appliance does not come up after rebooting and the serial port is connected to a terminal server (terminal concentrator), try the following:

Have an active session open on the terminal server, noting any traffic (characters) being output.

Unplug the terminal server from the appliance in case it is causing a problem (such as bad cabling).

Managing SG Appliance Systems

The SG appliance Systems tab displays the five available systems. Empty systems are indicated by the word Empty.

The system currently running is highlighted in blue and cannot be replaced or deleted.

From this screen, you can:

Select the SGOS system version to boot.

Lock one or more of the available SGOS system versions.

Select the SGOS system version to be replaced.

Delete one or more of the available SGOS system versions (CLI only).

View details of the available SGOS system versions.

To view SGOS system replacement options:

Select Maintenance > Upgrade > Systems.

To view details for an SGOS system version:

1.Select Maintenance > Upgrade > Systems.

2.Click Details next to the system for which you want to view detailed information; click OK when you are finished.