Chapter 3: EIU datafill 101

Table 26 Field descriptions for table EXNDINV for EIU datafill (continued)

Field

Subfield or refinement

Entry

Explanation and action

EN0LKALM

CR

External node no-link alarm

 

MJ

Enter the type of alarm to be raised if no

 

MN

links are available to the external node:

 

NA

CR (critical alarm)

 

 

 

 

MJ (major alarm)

 

 

MN (minor alarm)

 

 

NA (no alarm)

EN1LKALM

CR

External node one-link alarm

 

MJ

Enter the type of alarm to be raised if

 

MN

only one link is available to the external

 

NA

node.

ENALMSPT

Y or N

External node alarm scan points

 

 

This is a vector of up to two multiples.

 

 

Enter Y (yes) if scan points are to be

 

 

assigned to the node for alarm

 

 

purposes and datafill refinements

 

 

SCTMTYPE, SCTMNO, SCTMCTNO,

 

 

CRITSCPT, MAJSCPT, MINSCPT, and

 

 

SCCARDCD.

 

 

Otherwise, enter N (no). No further

 

 

datafill is required.

SCTMTYPE

MTM or OAU

Scan circuit trunk module type

 

 

Enter MTM if the scan circuit resides on

 

 

the maintenance trunk module (MTM).

 

 

Enter OAU if the scan circuit resides on

 

 

the office alarm unit (OAU).

SCTMNO

0 to 2047

Scan circuit trunk module number

 

 

Enter the trunk module (TM) of the MTM

 

 

where the scan circuit resides.

SCTMCTNO

0 to 29

Scan circuit trunk module circuit

 

 

number

 

 

Enter the circuit number on the MTM of

 

 

the scan circuit.

CRITSCPT

0 to 6

Critical alarm scan point

 

 

Enter the scan point associated with the

 

 

critical alarm for the node.

(Sheet 4 of 5)

DMS-100 Family EIU User Guide TELECOM12

Page 101
Image 101