Chapter 3: EIU datafill 71

Table 11 Field descriptions for table LIUINV for EIU datafill (continued)

Field

Subfield or refinement

Entry

Explanation and action

LIUSLOT

8 to 31

Link interface slot

 

 

Enter the slot number, at the host LIM,

 

 

on which the EIU resides.

 

 

The EIU occupies two card slots.

 

 

The left-most card represents the

 

 

logical location of the card.

 

 

All the shelves that are datafilled on a

 

 

particular controller must be of the

 

 

same type (two-slot shelves).

LOAD

alphanumeric

Software load name

 

(vector of up to 8 Enter the table software load name

 

characters)

applicable to the EIU.

 

 

This load is found in table PMLOADS.

PROCINFO

see subfield

Processor information

 

 

This field specifies the product

 

 

engineering code (PEC) of the

 

 

processors used in the LIU.

 

 

This field consists of subfield

 

 

PROCPEC.

PROCPEC

NTEX22BA or

Processor product engineering code

 

NTEX22BB

Enter the PEC of the processor card

 

NTEX22CA

used in the EIU as follows:

 

 

• NTEX22BA and NTEX22BB are the

 

 

PECs for the 8-Mbyte integrated

 

 

processor and F-bus interface

 

 

cards. The difference between the

 

 

NTEX22BA and NTEX22BB cards

 

 

is in firmware only, the hardware is

 

 

identical.

 

 

• NTEX22CA has a 32-Mbyte

 

 

integrated processor and F-bus

 

 

interface card.

CARDINFO

 

This field identifies the PEC of EIU

 

 

circuit packs. The EIC PEC code is

 

 

NT9X84AA and the Ethernet interface

 

 

paddle board (EIP) PEC code is

 

 

NT9X85AA.

(Sheet 3 of 4)

DMS-100 Family EIU User Guide TELECOM12

Page 71
Image 71
Cabletron Systems DMS-100 manual Link interface slot, Software load name, Processor information, Sheet 3