| Chapter 1: Introduction to the EIU 39 | |
|
|
|
|
|
| Table 1 |
|
| |
|
|
|
|
|
| Package | Title |
| Description |
|
|
|
|
|
| NTXF19AA | TCP/IP |
| This package is the protocol |
|
|
|
| software from the transport |
|
|
|
| layer down to the link layer. |
|
|
|
| NTXF19AA uses NTXF05AA. |
|
|
|
|
|
| NTXS11AA | FTP |
| This package is the standard |
|
|
|
| FTP client and server |
|
|
|
| software. NTXS11AA uses |
|
|
|
| NTXF19AA. |
|
|
|
|
|
| NTX70AA | Telnet/RMAP |
| This package is the standard |
|
|
|
| telnet server for remote MAP |
|
|
|
| (RMAP) access. |
|
|
|
|
|
| (Sheet 2 of 2) |
|
|
|
|
|
|
|
|
Software for peripheral processors is controlled through package lists that define the entities for a specific load. The EIU may have several loads depending upon the applications resident on it.
As of CSP02, the
EIU provisioning requirements
The provisioning rules for the total numbers of EIUs depend on the following requirements:
•the applications running on the EIUs
•the total application capacity required for all EIUs on the switch
•the level of redundancy required by these applications
The provisioning requirements are subject to the maximum limit of eight EIUs per switch.
The following sections describe the provisioning limits for the new components.
DMS-bus inter-MS provisioning
Each message switch in an IML requires an NT9X17DA port card and an NT9X20BB DS512 fiber paddle board.