Chapter 4: EIU maintenance 105
or the MAP display. The TST command in MAPCI also executes the same diagnostics when the EIU is ManB.
In-service diagnostics
The EIU changes its state to SysB state from InSv or IsTb if a serious hardware fault is detected by the
In-service leaky bucket audit
Several LAN errors can be detected by the EIC diagnostics software. However, these errors are not severe or fatal enough to be reported on every occurrence of the error. Most of these errors occur when the Ethernet LAN is carrying above average traffic. These errors are transient and therefore do not require the EIU to take any action. However, if these errors occur frequently, relative to the Ethernet traffic, it may be indicative of a faulty component on the LAN. The leaky bucket algorithm is applied to such errors before reporting them through
The leaky bucket algorithm measures errors against relative traffic and therefore allows the EIU to report faults only when a preset error count threshold is exceeded. The algorithm is controlled by five parameters:
•leaky bucket size
•fault detection threshold mark. The fault is reported when the bucket level exceeds this value.
•fault clear threshold mark. The fault reported previously, is cleared when the bucket level is lower than this value.
•error event factor. This value is added to the bucket level when an error event occurs.
•good event factor. This value is subtracted from the bucket level when a good event occurs.