Chapter 3: EIU datafill 93

 

 

 

 

Table 22 Field descriptions for table IPTHRON for EIU datafill (continued)

 

 

 

 

Field

Subfield or

Entry

Explanation and action

 

refinement

 

 

 

 

 

 

 

EIUINDEX

0 to 750

Ethernet interface unit index

 

 

 

If the entry in field SNNODE is EIU,

 

 

 

enter the EIU index.

 

 

 

Go to refinement TXCAPCT.

 

ELIUINDEX

0 to 750

Ethernet link interface unit index

 

 

 

If the entry in field SNNODE is ELIU,

 

 

 

enter the ELIU index.

 

 

 

Go to refinement TXCAPCT.

 

MSINDEX

0 to 1

Message switch index

 

 

 

If the entry in field SNNODE is MS,

 

 

 

enter the MS index.

 

 

 

Go to refinement TXCAPCT.

 

TXCAPCT

0 to 32767

Transmit capacity

 

 

 

Enter the IP transmission rate in kilobits

 

 

 

per second from node to node. The

 

 

 

node name and number are specified

 

 

 

as a key to this tuple.

 

 

 

 

(Sheet 3 of 3)

 

 

 

 

 

 

 

Sample datafill for table IPTHRON

Figure 19 shows sample datafill for table IPTHRON for an EIU.

Figure 19 Datafill example for table IPTHRON

LMSNODE TXCAPCT RXCAPCT

OPTION

-------------------------------------------------------------------------------

EIU 117 15

15

$

Table IPPROTO

Table IPPROTO is rarely used and normally does not need to be datafilled.

DMS-100 Family EIU User Guide TELECOM12

Page 93
Image 93
Cabletron Systems DMS-100 manual Table Ipproto, Sample datafill for table Ipthron, Ethernet link interface unit index