92Chapter 3: EIU datafill

Table 22 Field descriptions for table IPTHRON for EIU datafill (continued)

Field

Subfield or refinement

Entry

Explanation and action

OPTION

see subfield

Option

 

 

This field consists of subfield SNNODE.

SNNODE

AP,

SuperNode node

 

APU,

Enter the name of the SuperNode node.

 

CM,

The node must first be datafilled in its

 

EIU,

inventory table. For example, FP must

 

ELIU,

be datafilled in table APINV. Up to eight

 

FP,

nodes can be entered. If less than eight

 

or

are required, end the list with a $ (dollar

 

MS

sign).

 

 

Enter AP (application processor) and

 

 

datafill refinement SMNINDEX.

 

 

Enter APU and datafill refinement

 

 

APUINDEX.

 

 

Enter CM and go to refinement

 

 

TXCAPCT.

 

 

Enter EIU and datafill refinement

 

 

EIUINDEX.

 

 

Enter ELIU and datafill refinement

 

 

ELIUINDEX.

 

 

Enter FP (file processor) and datafill

 

 

refinement SMNINDEX.

 

 

Enter MS (message switch) and datafill

 

 

refinement MSINDEX.

SMNINDEX

0 to 99

Synchronized and matched node index

 

 

If the entry in field SNNODE is AP or

 

 

FP, enter the synchronized and

 

 

matched node (SMN) index.

 

 

Go to refinement TXCAPCT.

APUINDEX

0 to 750

Application processor unit index

 

 

If the entry in field SNNODE is APU,

 

 

enter the APU index.

 

 

Go to refinement TXCAPCT.

 

 

 

(Sheet 2 of 3)

 

 

297-8991-910 Standard 03.01 August 1999

Page 92
Image 92
Cabletron Systems DMS-100 Option, SuperNode node, Synchronized and matched node index, Application processor unit index