Chapter 3: EIU datafill 75

While table 12 provides all the information you need to datafill for EIUs, complete information on table IPNETWRK is in DMS-100 Translations Guide, 297-xxxx-350.

Table 12 Field descriptions for table IPNETWRK for EIU datafill

Field

Subfield or refinement

Entry

Explanation and action

KEYREF

refer to subfield

Key reference. This field consists of

 

 

subfield TAB_KEY.

TAB_KEY

0 to 15

Table key. Enter data in the network

 

 

interfaces. You can enter a maximum

 

 

of 16 entries.

CMIPADDR

IP address with

Computing module Internet Protocol.

 

four numbers

address. Enter the Internet Protocol

 

from 0 to 255

(IP) address of the CM. Separate each

 

 

number in the address with a single

 

 

space. For example, 47 2 86 122 is

 

 

equivalent to an IP address of

 

 

47.2.86.122.

SUBNET

1 to 23

Internet Protocol network subnet range.

 

 

Enter the range of the IP network

 

 

subnet mask bit width. Entries outside

 

 

the range indicated for this field are

 

 

invalid.

OPTION

refer to subfields

Option. This field consists of subfields

 

 

WORD_EIU and EIU_RNG. You can

 

 

enter up to a maximum of two options. If

 

 

you enter less than two options, end the

 

 

entry with a $.

 

 

This field defines the default EIU used

 

 

for routing.

WORD_EIU

EIU or

Ethernet interface unit. Enter EIU

 

EXTERNAL_

(Ethernet interface unit) or

 

ROUTER

EXTERNAL_ROUTER.

EIU_RNG

0 to 750

Ethernet interface unit range. Enter the

 

 

number that is assigned to the EIU.

PARMAREA

refer to subfields

Parameter area. This optional field

 

 

consists of subfield PARM. You can

 

 

enter a maximum of 12 multiples of this

 

 

field. If you enter less than 12 multiples,

 

 

end the list of entries with a $.

 

 

 

(Sheet 1 of 3)

 

 

DMS-100 Family EIU User Guide TELECOM12

Page 75
Image 75
Cabletron Systems DMS-100 manual Computing module Internet Protocol, Internet Protocol network subnet range