2-354
Catalyst 6500 Series Switch Command Reference—Release8.1
78-15474-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands set logging server
Command Types Switch command.
Command Modes Privileged.
Usage Guidelines You can also set the logging level by using the set logging level command. If you do not enter the facility
or server keywords, the parameter is applied to all levels.
Severity logging to a configured syslog server depends on the configuration set by the set logging level
command. The server severity level must be greater than or equal to the default severity level of the
message facility that you expect to receive in syslog messages on the syslog server.
Examples This example shows how to enable system message logging to the server:
Console> (enable) set logging server enable
System logging messages will be sent to the configured syslog servers.
Console> (enable)
This example shows how to disable system message logging to the server:
Console> (enable) set logging server disable
System logging messages will not be sent to the configured syslog servers.
Console> (enable)
This example shows how to add a server to the system logging server table using i ts IP add re ss:
Console> (enable) set logging server 171.69.192.205
171.69.192.205 added to the System logging server table.
Console> (enable)
This example shows how to globally set the syslog maximum severity control for all message type s:
Console> (enable) set logging server severity 4
System logging server severity set to 4(warnings).
Console> (enable)
Related Commands cl e ar l og gi ng s erver
show logging