2-934
Catalyst 6500 Series Switch Command Reference—Release8.1
78-15474-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands show port errdisable-timeout
show port errdisable-timeout
To display the configuration and status of the errdisable timeout for a particular port, use the show port
errdisable-timeout command.
show port errdisable-timeout [mod[/port]]
Syntax Description
Defaults This command has no default settings.
Command Types Switch command.
Command Modes Normal.
Usage Guidelines If the port is disabled and the reason is disabled globally, the NoChange value is displayed in the
Action on Timeout field regardless of the value in the Port ErrDisableTimeout field. If the port is not in
errdisabled state, the No Change value always is displayed in the Action on Timeout field.
Examples This example shows how to display the errdisable timeout configuration and status for a particular port:
Console> show port errdisable-timeout 3/3
Port Status ErrDisableReason Port ErrDisableTimeout Action on Timeout
---- ---------- ---------------- ---------------------- -----------------
3/3 errdisable udld Disable Remain Disabled
Console>
This example shows the output for a port in errdisabled state with the timeout flag enabled and with the
reason disabled:
Console> show port errdisable-timeout 3/3
Port Status ErrDisableReason Port ErrDisableTimeout Action on Timeout
---- ---------- ---------------- ---------------------- -----------------
3/3 errdisable udld Enable No Change
Console>
This example shows the output for a port in errdisabled state with the timeout flag enabled and with the
reason enabled:
Console> show port errdisable-timeout 3/3
Port Status ErrDisableReason Port ErrDisableTimeout Action on Timeout
---- ---------- ---------------- ---------------------- -----------------
3/3 errdisable udld Enable Enabled
Console>
mod[/port] (Optional) Number of the module and the port on the module.